Raylogic Centralized Solution

Bolt

KC - 10

10 button tactile press keypad, available with custom laser-engraved button labels

  • Freely configurable button actions, such as scene recall, channel turn on/off etc.
  • Configurable button behaviour: mutually exclusive, toggle or pushbutton
  • Enables simple master room control for users, staff etc.
  • Front panel scene selection
  • Pre-settable LED brightness indicators
  • Non-volatile memory for scenes and last state storage
  • Allows for multi-way control from entrance, bedside and additional locations

km-4

4 button soft-touch keypad

  • Freely configurable button actions, such as scene recall, channel turn on/off etc.
  • Configurable button behaviour: mutually exclusive, toggle or pushbutton
  • Enables simple master room control for users, staff etc.
  • Front panel scene selection
  • Pre-settable LED brightness indicators
  • Non-volatile memory for scenes and last state storage
  • Allows for multi-way control from entrance, bedside and additional locations
Bolt
Bolt

km-8

8 button soft-touch keypad

  • Freely configurable button actions, such as scene recall, channel turn on/off etc.
  • Configurable button behaviour: mutually exclusive, toggle or pushbutton
  • Enables simple master room control for users, staff etc.
  • Front panel scene selection
  • Pre-settable LED brightness indicators
  • Non-volatile memory for scenes and last state storage
  • Allows for multi-way control from entrance, bedside and additional locations

DIN-RE8

DIN Rail mounted 8 channel relay interface

  • Direct channel on/off control
  • Timed channel control
  • Timed control for curtains
  • 16 groups or areas
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
raylogic univo
raylogic univo

DIN-F8

DIN Rail mounted 8 channel analog 0-10V dimming system

  • Direct channel intensity and fade time control
  • Scene fade time programmable between 0 - 250 seconds
  • 16 groups or areas
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
  • Automatic frequency tracking and synchronization

DIN-H81

DIN Rail mounted 8 channel dimming system

  • Direct channel intensity and fade time control
  • Scene fade time programmable between 0 - 250 seconds
  • 16 groups or areas
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
  • Automatic frequency tracking and synchronization
raylogic univo
raylogic univo

DIN-HU4

DIN Rail mounted 4 channel universal dimming system

  • Direct channel intensity and fade time control
  • Scene fade time programmable between 0 - 250 seconds
  • 16 groups or areas
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
  • Automatic frequency tracking and synchronization

DIN-FN4

DIN Rail mounted 4 channel fan control system

  • 4 channels of hum-free ceiling fan control
  • Direct fan speed control with 5 speeds
  • 16 groups or areas
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
raylogic univo
raylogic univo

DIN-DALI-64

DIN Rail mounted 64 channel DALI control system

  • In-built power supply
  • In-built DALI power supply 200mA
  • Power supply for up to 2 Raylogic keypads
  • Direct RAYNET-DALI conversion
  • Direct interface with Raylogic ControlSoft for ease of programming
  • Support for DALI / DALI-2 including DT-6/DT-8 drivers
  • RAYNET mapping to DALI channel intensity
  • RAYNET mapping for areas to DALI groups
  • RAYNET mapping for scenes, for up to 16 DALI scenes
  • RAYNET mapping to DALI colour temperature / colour control

DIN-DMX512

DIN Rail mounted 512 channel DMX control system

  • Webserver for DMX512 fixture, scenes and sequence setup
  • Direct interface with Raylogic ControlSoft for ease of programming
  • Direct RAYNET-DMX512 conversion
  • RAYNET mapping to DMX512 channel intensity
  • RAYNET mapping for areas to DMX512 groups
  • RAYNET mapping for scenes to DMX512 scenes and sequences
  • Internal non-volatile memory for 60 scenes, schedules, timers and last state storage
  • In-built power supply
  • Power supply for up to 2 Raylogic keypads
raylogic univo
Bolt

kc -6/8/12

  • Elegant 6/8/12 push-button wall-mounting user interfaces, available in a wide range of contemporary finishes, with built-in IR sensors.
  • Modules for on-off switching with ultra-smooth dimming solutions for all types of LED strips and spots.
  • Leading and trailing edge products for the control of GLS lamps, tungsten filament bulbs and halogen lamps.
  • Control ceiling fans, occupancy and movement sensors, push-button switches and interface to third-party devices.